Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated current4A
Built-in depth69mm
Rated voltage400V
Frequency50 - 60Hz
Pollution degree3
Current limiting class3
Rated insulation voltage Ui440V
Over voltage category3
Release characteristicC
Degree of protection (IP)IP20
Width in number of modular spacings3
Number of protected poles3
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorNo
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0044 | S203M-C4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated current

4A

Built-in depth

69mm

Rated voltage

400V

Frequency

50 .. 60Hz

Pollution degree

3

Current limiting class

3

Rated insulation voltage Ui

440V

Over voltage category

3

Release characteristic

C

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Number of protected poles

3

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA