Aleta.hr
Main Product Image

2CDS273001R0061 | S203M-D6

Code: 1549971

ManufacturerABB
Catalog number2CDS273001R0061
EAN code4016779600972

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)3
Release characteristicD
Rated current6A
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Current limiting class3
Frequency50 - 60Hz
Suitable for flush-mounted installationNo
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Concurrently switching neutral conductorNo
Over voltage category3
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings3
Built-in depth69mm
Degree of protection (IP)IP20
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0061 | S203M-D6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Release characteristic

D

Rated current

6A

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Current limiting class

3

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Concurrently switching neutral conductor

Over voltage category

3

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

3

Built-in depth

69mm

Degree of protection (IP)

IP20

Pollution degree

3