Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Connectable conductor cross section multi-wired0 - 25mm²
Pollution degree3
Connectable conductor cross section solid-core0 - 35mm²
Current limiting class3
Width in number of modular spacings3
Over voltage category3
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Voltage typeAC
Rated current0.5A
Rated voltage400V
Release characteristicK
Number of protected poles3
Concurrently switching neutral conductorNo
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0157 | S203M-K0,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Connectable conductor cross section multi-wired

0 .. 25mm²

Pollution degree

3

Connectable conductor cross section solid-core

0 .. 35mm²

Current limiting class

3

Width in number of modular spacings

3

Over voltage category

3

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Voltage type

AC

Rated current

0.5A

Rated voltage

400V

Release characteristic

K

Number of protected poles

3

Concurrently switching neutral conductor

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.