Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Frequency50 - 60Hz
Rated voltage400V
Rated current20A
Built-in depth69mm
Current limiting class3
Release characteristicB
Over voltage category3
Width in number of modular spacings3
Rated insulation voltage Ui440V
Pollution degree3
Explosion-proofNo
Flush-mounted installationNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Power loss7.5W
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Number of protected poles3
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0205 | S203M-B20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated voltage

400V

Rated current

20A

Built-in depth

69mm

Current limiting class

3

Release characteristic

B

Over voltage category

3

Width in number of modular spacings

3

Rated insulation voltage Ui

440V

Pollution degree

3

Explosion-proof

Flush-mounted installation

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Power loss

7.5W

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Number of protected poles

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

3

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.