  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current1.6A
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Rated voltage400V
Voltage typeAC/DC
Built-in depth69mm
Over voltage category3
Release characteristicK
Pollution degree3
Current limiting class3
Width in number of modular spacings3
Number of protected poles3
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0257 | S203M-K1,6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

1.6A

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated voltage

400V

Voltage type

AC/DC

Built-in depth

69mm

Over voltage category

3

Release characteristic

K

Pollution degree

3

Current limiting class

3

Width in number of modular spacings

3

Number of protected poles

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.