Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Connectable conductor cross section solid-core0 - 35mm²
Explosion-proofNo
Current limiting class3
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 25mm²
Power loss8.1W
Over voltage category3
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Release characteristicZ
Rated voltage400V
Number of poles (total)3
Rated current10A
Number of protected poles3
Degree of protection (IP)IP20
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0428 | S203M-Z10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0 .. 35mm²

Explosion-proof

Current limiting class

3

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 25mm²

Power loss

8.1W

Over voltage category

3

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Release characteristic

Z

Rated voltage

400V

Number of poles (total)

3

Rated current

10A

Number of protected poles

3

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Concurrently switching neutral conductor

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.