Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Built-in depth69mm
Over voltage category3
Rated insulation voltage Ui440V
Current limiting class3
Pollution degree3
Suitable for flush-mounted installationNo
Width in number of modular spacings3
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)3
Release characteristicK
Number of protected poles3
Rated current25A
Rated voltage400V
Voltage typeAC
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0517 | S203M-K25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

69mm

Over voltage category

3

Rated insulation voltage Ui

440V

Current limiting class

3

Pollution degree

3

Suitable for flush-mounted installation

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Release characteristic

K

Number of protected poles

3

Rated current

25A

Rated voltage

400V

Voltage type

AC

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.