Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Frequency50 - 60Hz
Explosion-proofNo
Pollution degree3
Release characteristicC
Width in number of modular spacings3.0
Degree of protection (IP)IP20
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Power loss14.4W
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Built-in depth35mm
Rated current63A
Rated voltage400V
Rated insulation voltage Ui400V
Current limiting class63
Over voltage category400
Number of protected poles3
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 35mm²
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp400kV

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0634 | S203M-C63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Frequency

50 .. 60Hz

Explosion-proof

Pollution degree

3

Release characteristic

C

Width in number of modular spacings

3.0

Degree of protection (IP)

IP20

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Power loss

14.4W

Additional equipment possible

Concurrently switching neutral conductor

Built-in depth

35mm

Rated current

63A

Rated voltage

400V

Rated insulation voltage Ui

400V

Current limiting class

63

Over voltage category

400

Number of protected poles

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 35mm²

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

400kV