Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Number of poles (total)3
Rated current0.5A
Rated voltage400V
Number of protected poles3
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Voltage typeAC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Current limiting class3
Pollution degree3
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Degree of protection (IP)IP20
Frequency50 - 60Hz
Over voltage category3
Width in number of modular spacings3
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0984 | S203M-C0,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Number of poles (total)

3

Rated current

0.5A

Rated voltage

400V

Number of protected poles

3

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Current limiting class

3

Pollution degree

3

Additional equipment possible

Suitable for flush-mounted installation

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Over voltage category

3

Width in number of modular spacings

3

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.