Technical specifications

Rated voltage400V
Rated current6A
Frequency50 - 60Hz
Voltage typeAC/DC
Built-in depth71mm
Over voltage category3
Width in number of modular spacings4
Number of protected poles4
Pollution degree2
Current limiting class3
Degree of protection (IP)IP20
Release characteristicB
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0065 | S204M-B6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Rated current

6A

Frequency

50 .. 60Hz

Voltage type

AC/DC

Built-in depth

71mm

Over voltage category

3

Width in number of modular spacings

4

Number of protected poles

4

Pollution degree

2

Current limiting class

3

Degree of protection (IP)

IP20

Release characteristic

B

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Suitable for flush-mounted installation

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.