Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current10A
Voltage typeAC/DC
Built-in depth71mm
Frequency50 - 60Hz
Pollution degree2
Rated voltage400V
Degree of protection (IP)IP20
Release characteristicD
Width in number of modular spacings4
Over voltage category3
Current limiting class3
Rated insulation voltage Ui440V
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0101 | S204M-D10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

10A

Voltage type

AC/DC

Built-in depth

71mm

Frequency

50 .. 60Hz

Pollution degree

2

Rated voltage

400V

Degree of protection (IP)

IP20

Release characteristic

D

Width in number of modular spacings

4

Over voltage category

3

Current limiting class

3

Rated insulation voltage Ui

440V

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.