Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current1A
Voltage typeAC/DC
Built-in depth71mm
Current limiting class3
Pollution degree2
Rated voltage400V
Width in number of modular spacings4
Over voltage category3
Degree of protection (IP)IP20
Release characteristicK
Additional equipment possibleYes
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Connectable conductor cross section multi-wired0 - 25mm²
Concurrently switching neutral conductorNo
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core0 - 35mm²
Suitable for flush-mounted installationNo
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0217 | S204M-K1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

1A

Voltage type

AC/DC

Built-in depth

71mm

Current limiting class

3

Pollution degree

2

Rated voltage

400V

Width in number of modular spacings

4

Over voltage category

3

Degree of protection (IP)

IP20

Release characteristic

K

Additional equipment possible

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

0 .. 35mm²

Suitable for flush-mounted installation

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.