  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Frequency50 - 60Hz
Built-in depth71mm
Over voltage category3
Degree of protection (IP)IP20
Pollution degree2
Current limiting class3
Connectable conductor cross section solid-core0 - 35mm²
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 25mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Voltage typeAC
Rated current3A
Rated voltage400V
Release characteristicK
Width in number of modular spacings4
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0317 | S204M-K3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Built-in depth

71mm

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

2

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 35mm²

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Voltage type

AC

Rated current

3A

Rated voltage

400V

Release characteristic

K

Width in number of modular spacings

4

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.