Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Number of poles (total)4
Release characteristicK
Rated current4A
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC/DC
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Over voltage category3
Number of protected poles4
Built-in depth71mm
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Current limiting class3
Connectable conductor cross section solid-core0 - 35mm²
Concurrently switching neutral conductorNo
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Width in number of modular spacings4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0337 | S204M-K4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Number of poles (total)

4

Release characteristic

K

Rated current

4A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC/DC

Additional equipment possible

Suitable for flush-mounted installation

Over voltage category

3

Number of protected poles

4

Built-in depth

71mm

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 35mm²

Concurrently switching neutral conductor

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Width in number of modular spacings

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.