Technical specifications

Built-in depth71mm
Voltage typeAC/DC
Rated voltage400V
Rated current40A
Frequency50 - 60Hz
Over voltage category3
Current limiting class3
Pollution degree2
Degree of protection (IP)IP20
Width in number of modular spacings4
Rated insulation voltage Ui440V
Release characteristicB
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0405 | S204M-B40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

71mm

Voltage type

AC/DC

Rated voltage

400V

Rated current

40A

Frequency

50 .. 60Hz

Over voltage category

3

Current limiting class

3

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Rated insulation voltage Ui

440V

Release characteristic

B

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

4