Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth71mm
Voltage typeAC/DC
Concurrently switching neutral conductorNo
Number of poles (total)4
Release characteristicC
Ambient temperature during operating-25 - 55°C
Rated voltage400V
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Current limiting class3
Additional equipment possibleYes
Width in number of modular spacings4
Rated current50A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Number of protected poles4
Suitable for flush-mounted installationNo
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Frequency50 - 60Hz

Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0504 | S204M-C50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

71mm

Voltage type

AC/DC

Concurrently switching neutral conductor

Number of poles (total)

4

Release characteristic

C

Ambient temperature during operating

-25 .. 55°C

Rated voltage

400V

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Current limiting class

3

Additional equipment possible

Width in number of modular spacings

4

Rated current

50A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of protected poles

4

Suitable for flush-mounted installation

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Frequency

50 .. 60Hz

From same serie

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.