Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles4
Rated insulation voltage Ui440V
Release characteristicB
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Voltage typeAC/DC
Rated current50A
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Current limiting class3
Suitable for flush-mounted installationNo
Pollution degree2
Over voltage category3
Connectable conductor cross section multi-wired0 - 25mm²
Degree of protection (IP)IP20
Width in number of modular spacings4
Built-in depth71mm
Ambient temperature during operating-25 - 55°C
Rated voltage400V
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0505 | S204M-B50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Rated insulation voltage Ui

440V

Release characteristic

B

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Voltage type

AC/DC

Rated current

50A

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Current limiting class

3

Suitable for flush-mounted installation

Pollution degree

2

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Built-in depth

71mm

Ambient temperature during operating

-25 .. 55°C

Rated voltage

400V

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.