Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree2
Suitable for flush-mounted installationNo
Rated insulation voltage Ui440V
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Built-in depth71mm
Connectable conductor cross section solid-core0 - 35mm²
Concurrently switching neutral conductorNo
Over voltage category3
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Ambient temperature during operating-25 - 55°C
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Release characteristicC
Number of protected poles4
Rated current0.5A
Number of poles (total)4
Voltage typeAC
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Width in number of modular spacings4

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274001R0984 | S204M-C0,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

2

Suitable for flush-mounted installation

Rated insulation voltage Ui

440V

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Built-in depth

71mm

Connectable conductor cross section solid-core

0 .. 35mm²

Concurrently switching neutral conductor

Over voltage category

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Ambient temperature during operating

-25 .. 55°C

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Release characteristic

C

Number of protected poles

4

Rated current

0.5A

Number of poles (total)

4

Voltage type

AC

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Width in number of modular spacings

4

Related products