Aleta.hr
Main Product Image

2CDS281001R0084 | S201P-C8

Code: 1550257

ManufacturerABB
Catalog number2CDS281001R0084
EAN code4016779590242

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP2X
Voltage typeAC/DC
Built-in depth68mm
Suitable for flush-mounted installationNo
Width in number of modular spacings4
Rated voltage230V
Rated current8A
Release characteristicC
Ambient temperature during operating-25 - 55°C
Number of protected poles1
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 16mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Connectable conductor cross section solid-core0 - 25mm²
Rated impulse withstand voltage Uimp4kV
Over voltage category3
Rated insulation voltage Ui440V
Number of poles (total)1
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Pollution degree3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Power loss2.9W
Flush-mounted installationNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS281001R0084 | S201P-C8

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP2X

Voltage type

AC/DC

Built-in depth

68mm

Suitable for flush-mounted installation

Width in number of modular spacings

4

Rated voltage

230V

Rated current

8A

Release characteristic

C

Ambient temperature during operating

-25 .. 55°C

Number of protected poles

1

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 16mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Connectable conductor cross section solid-core

0 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Over voltage category

3

Rated insulation voltage Ui

440V

Number of poles (total)

1

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Pollution degree

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Power loss

2.9W

Flush-mounted installation

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.