Release characteristicD
Number of poles (total)2
Number of protected poles2
Rated voltage400V
Rated current40A
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Voltage typeAC/DC
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 25mm²
Pollution degree3
Over voltage category3
Connectable conductor cross section multi-wired0 - 16mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Built-in depth69mm
Ambient temperature during operating-25 - 55°C
Current limiting class3
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated impulse withstand voltage Uimp4kV
Power loss12.8W
Explosion-proofNo
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS282001R0401 | S202P-D40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Number of poles (total)

2

Number of protected poles

2

Rated voltage

400V

Rated current

40A

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 25mm²

Pollution degree

3

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 16mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Concurrently switching neutral conductor

Additional equipment possible

Built-in depth

69mm

Ambient temperature during operating

-25 .. 55°C

Current limiting class

3

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated impulse withstand voltage Uimp

4kV

Power loss

12.8W

Explosion-proof

Flush-mounted installation