2CDS283001R0087 | S203P-K0,2

Code: 1550502

ManufacturerABB
Catalog number2CDS283001R0087
EAN code4016779597005

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Number of poles (total)3
Built-in depth69mm
Rated current0.2A
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated insulation voltage Ui440V
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Power loss5.1W
Flush-mounted installationNo
Over voltage category3
Pollution degree3
Width in number of modular spacings3.0
Additional equipment possibleYes
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 16mm²
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS283001R0087 | S203P-K0,2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Number of poles (total)

3

Built-in depth

69mm

Rated current

0.2A

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated insulation voltage Ui

440V

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Power loss

5.1W

Flush-mounted installation

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

3.0

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 16mm²

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.