Technical specifications

Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Built-in depth69mm
Release characteristicK
Number of protected poles3
Rated current0.3A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Power loss5.4W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Rated voltage400V
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Voltage typeOther
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree3
Flush-mounted installationNo
Explosion-proofNo
Degree of protection (IP)IP20
Width in number of modular spacings3.0
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 16mm²
Connectable conductor cross section solid-core0.75 - 25mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS283001R0117 | S203P-K0,3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Built-in depth

69mm

Release characteristic

K

Number of protected poles

3

Rated current

0.3A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Power loss

5.4W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated voltage

400V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Voltage type

Other

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

3

Flush-mounted installation

Explosion-proof

Degree of protection (IP)

IP20

Width in number of modular spacings

3.0

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 16mm²

Connectable conductor cross section solid-core

0.75 .. 25mm²

Additional equipment possible