Technical specifications

Rated current13A
Release characteristicB
Number of protected poles3
Number of poles (total)3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Rated voltage400V
Concurrently switching neutral conductorNo
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings3
Degree of protection (IP)IP20
Pollution degree3
Over voltage category3
Connectable conductor cross section multi-wired0 - 16mm²
Connectable conductor cross section solid-core0 - 25mm²
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Built-in depth69mm
Explosion-proofNo
Flush-mounted installationNo
Power loss-W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS283001R0135 | S203P-B13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

13A

Release characteristic

B

Number of protected poles

3

Number of poles (total)

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated voltage

400V

Concurrently switching neutral conductor

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Pollution degree

3

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 16mm²

Connectable conductor cross section solid-core

0 .. 25mm²

Additional equipment possible

Suitable for flush-mounted installation

Built-in depth

69mm

Explosion-proof

Flush-mounted installation

Power loss

-W

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.