Aleta.hr
Main Product Image

2CDS283001R0255 | S203P-B25

Code: 1550523

ManufacturerABB
Catalog number2CDS283001R0255
EAN code4016779597210

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Rated current25A
Number of protected poles3
Number of poles (total)3
Rated voltage400V
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Over voltage category3
Width in number of modular spacings3
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Current limiting class3
Pollution degree3
Degree of protection (IP)IP20
Built-in depth69mm
Connectable conductor cross section multi-wired0 - 16mm²
Flush-mounted installationNo
Explosion-proofNo
Power loss10.5W

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS283001R0255 | S203P-B25

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated current

25A

Number of protected poles

3

Number of poles (total)

3

Rated voltage

400V

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Over voltage category

3

Width in number of modular spacings

3

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Current limiting class

3

Pollution degree

3

Degree of protection (IP)

IP20

Built-in depth

69mm

Connectable conductor cross section multi-wired

0 .. 16mm²

Flush-mounted installation

Explosion-proof

Power loss

10.5W

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.