Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current6A
Built-in depth69mm
Voltage typeAC
Current limiting class3
Pollution degree3
Frequency50 - 60Hz
Over voltage category3
Width in number of modular spacings3
Release characteristicK
Rated insulation voltage Ui440V
Rated voltage400V
Concurrently switching neutral conductorNo
Number of protected poles3
Connectable conductor cross section multi-wired0 - 16mm²
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 25mm²
Power loss7.2W
Explosion-proofNo
Flush-mounted installationNo
Degree of protection (IP)IP20
Number of poles (total)3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS283001R0377 | S203P-K6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Built-in depth

69mm

Voltage type

AC

Current limiting class

3

Pollution degree

3

Frequency

50 .. 60Hz

Over voltage category

3

Width in number of modular spacings

3

Release characteristic

K

Rated insulation voltage Ui

440V

Rated voltage

400V

Concurrently switching neutral conductor

Number of protected poles

3

Connectable conductor cross section multi-wired

0 .. 16mm²

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 25mm²

Power loss

7.2W

Explosion-proof

Flush-mounted installation

Degree of protection (IP)

IP20

Number of poles (total)

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.