Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Built-in depth69mm
Rated insulation voltage Ui440V
Rated current0.5A
Release characteristicZ
Voltage typeAC
Rated voltage400V
Pollution degree3
Current limiting class3
Number of protected poles4
Width in number of modular spacings4
Power loss-W
Over voltage category3
Degree of protection (IP)IP20
Explosion-proofNo
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 16mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Connectable conductor cross section solid-core0 - 25mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Concurrently switching neutral conductorNo
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS284001R0158 | S204P-Z0,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

69mm

Rated insulation voltage Ui

440V

Rated current

0.5A

Release characteristic

Z

Voltage type

AC

Rated voltage

400V

Pollution degree

3

Current limiting class

3

Number of protected poles

4

Width in number of modular spacings

4

Power loss

-W

Over voltage category

3

Degree of protection (IP)

IP20

Explosion-proof

Additional equipment possible

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 16mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Connectable conductor cross section solid-core

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Concurrently switching neutral conductor

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.