Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current16A
Number of protected poles4
Release characteristicD
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Over voltage category3
Current limiting class3
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Pollution degree3
Width in number of modular spacings4
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Frequency50 - 60Hz
Built-in depth69mm
Connectable conductor cross section multi-wired0 - 16mm²
Number of poles (total)4
Connectable conductor cross section solid-core0 - 25mm²
Voltage typeAC
Explosion-proofNo
Flush-mounted installationNo
Power loss10W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS284001R0161 | S204P-D16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

16A

Number of protected poles

4

Release characteristic

D

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Over voltage category

3

Current limiting class

3

Additional equipment possible

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Pollution degree

3

Width in number of modular spacings

4

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Frequency

50 .. 60Hz

Built-in depth

69mm

Connectable conductor cross section multi-wired

0 .. 16mm²

Number of poles (total)

4

Connectable conductor cross section solid-core

0 .. 25mm²

Voltage type

AC

Explosion-proof

Flush-mounted installation

Power loss

10W

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.