Aleta.hr
Main Product Image

2CDS284001R0254 | S204P-C25

Code: 1550682

ManufacturerABB
Catalog number2CDS284001R0254
EAN code4016779612418

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Number of poles (total)4
Rated current25A
Number of protected poles4
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Frequency50 - 60Hz
Width in number of modular spacings4
Over voltage category3
Rated voltage400V
Concurrently switching neutral conductorNo
Pollution degree3
Built-in depth69mm
Connectable conductor cross section solid-core0 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Rated impulse withstand voltage Uimp4kV
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 16mm²
Ambient temperature during operating-25 - 55°C
Power loss14W
Explosion-proofNo
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS284001R0254 | S204P-C25

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Number of poles (total)

4

Rated current

25A

Number of protected poles

4

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Frequency

50 .. 60Hz

Width in number of modular spacings

4

Over voltage category

3

Rated voltage

400V

Concurrently switching neutral conductor

Pollution degree

3

Built-in depth

69mm

Connectable conductor cross section solid-core

0 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated impulse withstand voltage Uimp

4kV

Suitable for flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 16mm²

Ambient temperature during operating

-25 .. 55°C

Power loss

14W

Explosion-proof

Flush-mounted installation

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.