Technical specifications

Number of protected poles4
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Rated current63A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Rated insulation voltage Ui440V
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Current limiting class3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Suitable for flush-mounted installationNo
Voltage typeAC
Built-in depth69mm
Additional equipment possibleYes
Release characteristicD
Pollution degree3
Degree of protection (IP)IP20
Width in number of modular spacings4
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 16mm²
Connectable conductor cross section solid-core0 - 25mm²
Frequency50 - 60Hz
Explosion-proofNo
Power loss22.4W
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS284001R0631 | S204P-D63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Rated current

63A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated insulation voltage Ui

440V

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Suitable for flush-mounted installation

Voltage type

AC

Built-in depth

69mm

Additional equipment possible

Release characteristic

D

Pollution degree

3

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 16mm²

Connectable conductor cross section solid-core

0 .. 25mm²

Frequency

50 .. 60Hz

Explosion-proof

Power loss

22.4W

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.