Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Release characteristicB
Rated current63A
Rated insulation voltage Ui440V
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V12.5kA
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Frequency50 - 60Hz
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Voltage typeAC
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Over voltage category3
Pollution degree3
Width in number of modular spacings4
Ambient temperature during operating-25 - 55°C
Degree of protection (IP)IP20
Built-in depth69mm
Connectable conductor cross section multi-wired0 - 16mm²
Connectable conductor cross section solid-core0 - 25mm²
Explosion-proofNo
Power loss22.4W
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS284001R0635 | S204P-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Release characteristic

B

Rated current

63A

Rated insulation voltage Ui

440V

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Frequency

50 .. 60Hz

Additional equipment possible

Concurrently switching neutral conductor

Voltage type

AC

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Built-in depth

69mm

Connectable conductor cross section multi-wired

0 .. 16mm²

Connectable conductor cross section solid-core

0 .. 25mm²

Explosion-proof

Power loss

22.4W

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.