Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current0.03A
Rated current16A
Rated voltage240V
Voltage typeAC
Release characteristicB
Width in number of modular spacings2
Current limiting class3
Surge current capacity-kA
Leakage current typeA
Rated insulation voltage Ui500V
Power loss3.4W
Over voltage category3
Built-in depth69mm
Pollution degree2
Number of protected poles2
Degree of protection (IP)IP2X
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core25 - 25mm²
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Number of poles (total)2
Connectable conductor cross section multi-wired25 - 25mm²
With interlocking deviceYes
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR252140R1165 | DS202C B16 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current

0.03A

Rated current

16A

Rated voltage

240V

Voltage type

AC

Release characteristic

B

Width in number of modular spacings

2

Current limiting class

3

Surge current capacity

-kA

Leakage current type

A

Rated insulation voltage Ui

500V

Power loss

3.4W

Over voltage category

3

Built-in depth

69mm

Pollution degree

2

Number of protected poles

2

Degree of protection (IP)

IP2X

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

25 .. 25mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Number of poles (total)

2

Connectable conductor cross section multi-wired

25 .. 25mm²

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.