Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP2X
Rated voltage240V
Rated insulation voltage Ui500V
Built-in depth69mm
Surge current capacity-kA
Leakage current typeA
Rated fault current0.03A
Current limiting class3
Rated current20A
Width in number of modular spacings2
Frequency50/60 Hz
Number of protected poles2
Release characteristicC
Power loss4.4W
Pollution degree2
Over voltage category3
Concurrently switching neutral conductorYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Voltage typeAC
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
With interlocking deviceYes
Number of poles (total)2
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core25 - 25mm²
Connectable conductor cross section multi-wired25 - 25mm²
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR252140R1204 | DS202C C20 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP2X

Rated voltage

240V

Rated insulation voltage Ui

500V

Built-in depth

69mm

Surge current capacity

-kA

Leakage current type

A

Rated fault current

0.03A

Current limiting class

3

Rated current

20A

Width in number of modular spacings

2

Frequency

50/60 Hz

Number of protected poles

2

Release characteristic

C

Power loss

4.4W

Pollution degree

2

Over voltage category

3

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Voltage type

AC

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Number of poles (total)

2

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section solid-core

25 .. 25mm²

Connectable conductor cross section multi-wired

25 .. 25mm²

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.