Technical specifications

Suitable for flush-mounted installationNo
Number of poles (total)2
Number of protected poles2
Rated voltage240V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current16A
Rated fault current0.3A
Leakage current typeA
Current limiting class3
Power loss3.4W
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicB
Concurrently switching neutral conductorYes
With interlocking deviceYes
Over voltage category3
Pollution degree2
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings2
Built-in depth69mm
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Degree of protection (IP)IP2X
Connectable conductor cross section solid-core25 - 25mm²
Connectable conductor cross section multi-wired25 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR252140R3165 | DS202C B16 A300

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Number of poles (total)

2

Number of protected poles

2

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

16A

Rated fault current

0.3A

Leakage current type

A

Current limiting class

3

Power loss

3.4W

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

B

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

2

Built-in depth

69mm

Flush-mounted installation

Anti-nuisance tripping version

Degree of protection (IP)

IP2X

Connectable conductor cross section solid-core

25 .. 25mm²

Connectable conductor cross section multi-wired

25 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.