Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage240V
Voltage typeAC
Over voltage category3
Pollution degree2
Built-in depth69mm
Rated fault current0.3A
Surge current capacity0.25kA
Leakage current typeA
Rated current20A
Release characteristicB
Rated insulation voltage Ui500V
Current limiting class3
Power loss4.4W
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-210kA
Suitable for flush-mounted installationNo
Width in number of modular spacings2
Degree of protection (IP)IP2X
Frequency50/60 Hz
Number of protected poles2
Connectable conductor cross section solid-core25 - 25mm²
Connectable conductor cross section multi-wired25 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Ambient temperature during operating-25 - 55°C
With interlocking deviceYes
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Number of poles (total)2
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR252140R3205 | DS202C B20 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

240V

Voltage type

AC

Over voltage category

3

Pollution degree

2

Built-in depth

69mm

Rated fault current

0.3A

Surge current capacity

0.25kA

Leakage current type

A

Rated current

20A

Release characteristic

B

Rated insulation voltage Ui

500V

Current limiting class

3

Power loss

4.4W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Suitable for flush-mounted installation

Width in number of modular spacings

2

Degree of protection (IP)

IP2X

Frequency

50/60 Hz

Number of protected poles

2

Connectable conductor cross section solid-core

25 .. 25mm²

Connectable conductor cross section multi-wired

25 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Ambient temperature during operating

-25 .. 55°C

With interlocking device

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Number of poles (total)

2

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.