Voltage typeAC
Rated voltage240V
Built-in depth69mm
Rated current16A
Rated fault current0.01A
Power loss5.4W
Current limiting class3
Release characteristicC
Surge current capacity-kA
Pollution degree2
Leakage current typeA
Over voltage category3
Rated insulation voltage Ui500V
Degree of protection (IP)IP2X
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section multi-wired25 - 25mm²
With interlocking deviceYes
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core25 - 25mm²
Ambient temperature during operating-25 - 55°C
Frequency50/60 Hz
Suitable for flush-mounted installationNo
Number of protected poles2
Width in number of modular spacings2
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR272140R0164 | DS202C M C16 A10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated voltage

240V

Built-in depth

69mm

Rated current

16A

Rated fault current

0.01A

Power loss

5.4W

Current limiting class

3

Release characteristic

C

Surge current capacity

-kA

Pollution degree

2

Leakage current type

A

Over voltage category

3

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP2X

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section multi-wired

25 .. 25mm²

With interlocking device

Flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

25 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Frequency

50/60 Hz

Suitable for flush-mounted installation

Number of protected poles

2

Width in number of modular spacings

2

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed