Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Built-in depth69mm
Rated voltage240V
Rated fault current0.03A
Current limiting class3
Surge current capacity-kA
Rated current6A
Rated insulation voltage Ui500V
Width in number of modular spacings2
Connectable conductor cross section multi-wired25 - 25mm²
Pollution degree2
Frequency50/60 Hz
Power loss8.1W
Connectable conductor cross section solid-core25 - 25mm²
Number of protected poles2
Over voltage category3
Release characteristicB
Rated short-circuit breaking capacity according to IEC 60947-210kA
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorYes
Degree of protection (IP)IP2X
With interlocking deviceYes
Leakage current typeA
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Number of poles (total)2
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR272140R1065 | DS202C M B6 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

69mm

Rated voltage

240V

Rated fault current

0.03A

Current limiting class

3

Surge current capacity

-kA

Rated current

6A

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

25 .. 25mm²

Pollution degree

2

Frequency

50/60 Hz

Power loss

8.1W

Connectable conductor cross section solid-core

25 .. 25mm²

Number of protected poles

2

Over voltage category

3

Release characteristic

B

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Degree of protection (IP)

IP2X

With interlocking device

Leakage current type

A

Anti-nuisance tripping version

Flush-mounted installation

Number of poles (total)

2

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.