Technical specifications

Rated voltage240V
Voltage typeAC
Rated current10A
Rated insulation voltage Ui500V
Release characteristicC
Rated fault current0.03A
Built-in depth69mm
Width in number of modular spacings2
Over voltage category3
Pollution degree2
Surge current capacity-kA
Leakage current typeA
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-210kA
With interlocking deviceYes
Frequency50/60 Hz
Power loss4.1W
Number of protected poles2
Connectable conductor cross section multi-wired25 - 25mm²
Degree of protection (IP)IP2X
Connectable conductor cross section solid-core25 - 25mm²
Concurrently switching neutral conductorYes
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR272140R1104 | DS202C M C10 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

240V

Voltage type

AC

Rated current

10A

Rated insulation voltage Ui

500V

Release characteristic

C

Rated fault current

0.03A

Built-in depth

69mm

Width in number of modular spacings

2

Over voltage category

3

Pollution degree

2

Surge current capacity

-kA

Leakage current type

A

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

With interlocking device

Frequency

50/60 Hz

Power loss

4.1W

Number of protected poles

2

Connectable conductor cross section multi-wired

25 .. 25mm²

Degree of protection (IP)

IP2X

Connectable conductor cross section solid-core

25 .. 25mm²

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

10kA