Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage240V
Rated current25A
Voltage typeAC
Built-in depth69mm
Leakage current typeA
Over voltage category3
Surge current capacity-kA
Current limiting class3
Release characteristicC
Rated fault current0.03A
Rated insulation voltage Ui500V
Power loss5.5W
Degree of protection (IP)IP2X
Concurrently switching neutral conductorYes
Width in number of modular spacings2
Suitable for flush-mounted installationNo
Pollution degree2
Number of protected poles2
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core25 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired25 - 25mm²
Disconnection characteristicUndelayed
With interlocking deviceYes
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR272140R1254 | DS202C M C25 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

240V

Rated current

25A

Voltage type

AC

Built-in depth

69mm

Leakage current type

A

Over voltage category

3

Surge current capacity

-kA

Current limiting class

3

Release characteristic

C

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Power loss

5.5W

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Width in number of modular spacings

2

Suitable for flush-mounted installation

Pollution degree

2

Number of protected poles

2

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

25 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

25 .. 25mm²

Disconnection characteristic

Undelayed

With interlocking device

Anti-nuisance tripping version

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.