Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current0.3A
Rated insulation voltage Ui500V
Release characteristicB
Leakage current typeA
Voltage typeAC
Built-in depth69mm
Rated voltage240V
Rated current10A
Width in number of modular spacings2
Current limiting class3
Surge current capacity-kA
Over voltage category3
Power loss4.1W
Pollution degree2
Number of protected poles2
Frequency50/60 Hz
Degree of protection (IP)IP2X
Concurrently switching neutral conductorYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core25 - 25mm²
Rated short-circuit breaking capacity according to EN 6100910kA
Flush-mounted installationNo
Connectable conductor cross section multi-wired25 - 25mm²
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
With interlocking deviceYes
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR272140R3105 | DS202C M B10 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current

0.3A

Rated insulation voltage Ui

500V

Release characteristic

B

Leakage current type

A

Voltage type

AC

Built-in depth

69mm

Rated voltage

240V

Rated current

10A

Width in number of modular spacings

2

Current limiting class

3

Surge current capacity

-kA

Over voltage category

3

Power loss

4.1W

Pollution degree

2

Number of protected poles

2

Frequency

50/60 Hz

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

25 .. 25mm²

Rated short-circuit breaking capacity according to EN 61009

10kA

Flush-mounted installation

Connectable conductor cross section multi-wired

25 .. 25mm²

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 55°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.