Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Built-in depth76mm
Voltage typeAC/DC
Frequency0 - 60Hz
Rated voltage230V
Rated current2A
Degree of protection (IP)IP20
Over voltage category3
Pollution degree2
Width in number of modular spacings2
Current limiting class3
Rated insulation voltage Ui500V
Number of protected poles1
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 16mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V4.5kA
Connectable conductor cross section multi-wired0 - 10mm²
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V4.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V4.5kA
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS245101R0024 | SN201 L C2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Built-in depth

76mm

Voltage type

AC/DC

Frequency

0 .. 60Hz

Rated voltage

230V

Rated current

2A

Degree of protection (IP)

IP20

Over voltage category

3

Pollution degree

2

Width in number of modular spacings

2

Current limiting class

3

Rated insulation voltage Ui

500V

Number of protected poles

1

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 16mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

4.5kA

Connectable conductor cross section multi-wired

0 .. 10mm²

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

4.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

4.5kA

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.