Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage230V
Pollution degree2
Rated current4A
Concurrently switching neutral conductorYes
Number of protected poles1
Frequency0 - 60Hz
Rated insulation voltage Ui500V
Release characteristicB
Over voltage category3
Degree of protection (IP)IP20
Current limiting class3
Voltage typeAC/DC
Suitable for flush-mounted installationNo
Built-in depth76mm
Width in number of modular spacings2
Number of poles (total)2
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V4.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V4.5kA
Connectable conductor cross section solid-core0 - 16mm²
Connectable conductor cross section multi-wired0 - 10mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V4.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS245101R0045 | SN201 L B4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Pollution degree

2

Rated current

4A

Concurrently switching neutral conductor

Number of protected poles

1

Frequency

0 .. 60Hz

Rated insulation voltage Ui

500V

Release characteristic

B

Over voltage category

3

Degree of protection (IP)

IP20

Current limiting class

3

Voltage type

AC/DC

Suitable for flush-mounted installation

Built-in depth

76mm

Width in number of modular spacings

2

Number of poles (total)

2

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

4.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

4.5kA

Connectable conductor cross section solid-core

0 .. 16mm²

Connectable conductor cross section multi-wired

0 .. 10mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

4.5kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.