Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth76mm
Voltage typeAC/DC
Release characteristicC
Rated voltage230V
Frequency0 - 60Hz
Rated current6A
Pollution degree2
Current limiting class3
Rated insulation voltage Ui500V
Over voltage category3
Suitable for flush-mounted installationNo
Width in number of modular spacings2
Number of protected poles1
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Number of poles (total)2
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 16mm²
Connectable conductor cross section multi-wired0 - 10mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V4.5kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V4.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V4.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS245101R0064 | SN201 L C6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

76mm

Voltage type

AC/DC

Release characteristic

C

Rated voltage

230V

Frequency

0 .. 60Hz

Rated current

6A

Pollution degree

2

Current limiting class

3

Rated insulation voltage Ui

500V

Over voltage category

3

Suitable for flush-mounted installation

Width in number of modular spacings

2

Number of protected poles

1

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Number of poles (total)

2

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 16mm²

Connectable conductor cross section multi-wired

0 .. 10mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

4.5kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

4.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

4.5kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.