Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated insulation voltage Ui500V
Pollution degree2
Over voltage category3
Rated voltage230V
Degree of protection (IP)IP2X
Concurrently switching neutral conductorYes
Current limiting class3
Rated current20A
Width in number of modular spacings2
Release characteristicB
Number of protected poles1
Suitable for flush-mounted installationNo
Frequency0 - 60Hz
Built-in depth76mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V4.5kA
Ambient temperature during operating-25 - 55°C
Number of poles (total)2
Connectable conductor cross section multi-wired0 - 10mm²
Connectable conductor cross section solid-core0 - 16mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V4.5kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V4.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS245101R0205 | SN201 L B20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated insulation voltage Ui

500V

Pollution degree

2

Over voltage category

3

Rated voltage

230V

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Current limiting class

3

Rated current

20A

Width in number of modular spacings

2

Release characteristic

B

Number of protected poles

1

Suitable for flush-mounted installation

Frequency

0 .. 60Hz

Built-in depth

76mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

4.5kA

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

2

Connectable conductor cross section multi-wired

0 .. 10mm²

Connectable conductor cross section solid-core

0 .. 16mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

4.5kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

4.5kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.