Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency0 - 60Hz
Built-in depth76mm
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP20
Pollution degree2
Connectable conductor cross section solid-core0 - 16mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V4.5kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 10mm²
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V4.5kA
Rated insulation voltage Ui500V
Ambient temperature during operating-25 - 55°C
Over voltage category3
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V4.5kA
Number of poles (total)2
Rated current25A
Rated voltage230V
Width in number of modular spacings1
Concurrently switching neutral conductorYes
Voltage typeAC
Release characteristicB
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS245101R0255 | SN201 L B25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

0 .. 60Hz

Built-in depth

76mm

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Pollution degree

2

Connectable conductor cross section solid-core

0 .. 16mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

4.5kA

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 10mm²

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

4.5kA

Rated insulation voltage Ui

500V

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

4.5kA

Number of poles (total)

2

Rated current

25A

Rated voltage

230V

Width in number of modular spacings

1

Concurrently switching neutral conductor

Voltage type

AC

Release characteristic

B