Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP2X
Built-in depth76mm
Pollution degree2
Current limiting class3
Rated insulation voltage Ui500V
Over voltage category3
Frequency0 - 60Hz
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 16mm²
Connectable conductor cross section multi-wired0 - 10mm²
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V4.5kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V4.5kA
Additional equipment possibleYes
Rated current32A
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V4.5kA
Voltage typeAC
Concurrently switching neutral conductorYes
Rated voltage230V
Number of protected poles1
Number of poles (total)2
Width in number of modular spacings1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS245101R0324 | SN201 L C32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP2X

Built-in depth

76mm

Pollution degree

2

Current limiting class

3

Rated insulation voltage Ui

500V

Over voltage category

3

Frequency

0 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 16mm²

Connectable conductor cross section multi-wired

0 .. 10mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

4.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

4.5kA

Additional equipment possible

Rated current

32A

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

4.5kA

Voltage type

AC

Concurrently switching neutral conductor

Rated voltage

230V

Number of protected poles

1

Number of poles (total)

2

Width in number of modular spacings

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.