Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth76mm
Release characteristicB
Number of poles (total)2
Rated voltage230V
Rated current10A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of protected poles1
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Frequency0 - 50Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Current limiting class3
Pollution degree2
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Width in number of modular spacings2
Connectable conductor cross section solid-core0 - 16mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 10mm²
Ambient temperature during operating-25 - 55°C
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS255101R0105 | SN201 B10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

76mm

Release characteristic

B

Number of poles (total)

2

Rated voltage

230V

Rated current

10A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Frequency

0 .. 50Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Current limiting class

3

Pollution degree

2

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

2

Connectable conductor cross section solid-core

0 .. 16mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 10mm²

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.