Aleta.hr
Main Product Image

2CSS255101R0255 | SN201 B25

Code: 1560091

ManufacturerRAZNO
Catalog number2CSS255101R0255
Type
EAN code8012542091158

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Frequency

0 - 50Hz

Rated current

25A

Release characteristic

B

Voltage type

AC/DC

Suitable for flush-mounted installation

No

Rated voltage

230V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Current limiting class

3

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Width in number of modular spacings

2

Concurrently switching neutral conductor

Yes

Number of protected poles

1

Degree of protection (IP)

IP20

Additional equipment possible

Yes

Connectable conductor cross section solid-core

0 - 16mm²

Connectable conductor cross section multi-wired

0 - 10mm²

Built-in depth

76mm

Ambient temperature during operating

-25 - 55°C

Pollution degree

2

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CSS255101R0255 | SN201 B25

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Frequency

0 .. 50Hz

Rated current

25A

Release characteristic

B

Voltage type

AC/DC

Suitable for flush-mounted installation

Rated voltage

230V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Current limiting class

3

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Width in number of modular spacings

2

Concurrently switching neutral conductor

Number of protected poles

1

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 16mm²

Connectable conductor cross section multi-wired

0 .. 10mm²

Built-in depth

76mm

Ambient temperature during operating

-25 .. 55°C

Pollution degree

2

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.