Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Frequency0 - 50Hz
Voltage typeAC/DC
Rated insulation voltage Ui500V
Rated current10A
Pollution degree2
Over voltage category3
Built-in depth69mm
Release characteristicC
Rated voltage230V
Number of protected poles1
Width in number of modular spacings2
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 10mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0 - 16mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS275101R0104 | SN201 M C10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Frequency

0 .. 50Hz

Voltage type

AC/DC

Rated insulation voltage Ui

500V

Rated current

10A

Pollution degree

2

Over voltage category

3

Built-in depth

69mm

Release characteristic

C

Rated voltage

230V

Number of protected poles

1

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 10mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0 .. 16mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Suitable for flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.