Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage230V
Rated current16A
Release characteristicB
Frequency0 - 50Hz
Voltage typeAC/DC
Built-in depth69mm
Degree of protection (IP)IP2X
Rated insulation voltage Ui500V
Over voltage category3
Current limiting class3
Pollution degree2
Number of protected poles1
Width in number of modular spacings2
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 16mm²
Number of poles (total)2
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section multi-wired0 - 10mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS275101R0165 | SN201 M B16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Rated current

16A

Release characteristic

B

Frequency

0 .. 50Hz

Voltage type

AC/DC

Built-in depth

69mm

Degree of protection (IP)

IP2X

Rated insulation voltage Ui

500V

Over voltage category

3

Current limiting class

3

Pollution degree

2

Number of protected poles

1

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 16mm²

Number of poles (total)

2

Concurrently switching neutral conductor

Additional equipment possible

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section multi-wired

0 .. 10mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.