Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Release characteristicC
Rated voltage230V
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Frequency0 - 50Hz
Voltage typeAC/DC
Rated current20A
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorYes
Over voltage category3
Current limiting class3
Width in number of modular spacings2
Pollution degree2
Additional equipment possibleYes
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 10mm²
Connectable conductor cross section solid-core0 - 16mm²
Built-in depth69mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS275101R0204 | SN201 M C20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Release characteristic

C

Rated voltage

230V

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Frequency

0 .. 50Hz

Voltage type

AC/DC

Rated current

20A

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Current limiting class

3

Width in number of modular spacings

2

Pollution degree

2

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 10mm²

Connectable conductor cross section solid-core

0 .. 16mm²

Built-in depth

69mm